AC Power Corp.
Product Name:
ASU-series
Description:
1. Double Conversion - True On-Line UPS with zero transfer time.
2. IGBT / PWM technology for high efficiency & high reliability. Small size and
low noise.
3. Microprocessor Control with fast and precise response.
4. Pure Sine Wave Output , and low THD
5. High input power factor (>0.95)
Safe
1. Self test while start of the UPS.
2. Cold start function - The UPS can be started with battery for emergent power
on.
3. Protection against all type of power problems.
4. Site wiring fault warning (1~3kVA)
5. Built-in maintenance bypass switch (6~20kVA).
6. Meet EN50091-2 & IEC61000-4 Standards.
Flexibilty
1. High reliable parallel function (3 pcs Max for 6~20kVA).
2. RS-232 & Intelligent slot communication port.
3. Support Win98 , 2000 , XP ,NT , and Linux systems with monitor software.
4. Wide input voltage range to support major brands of generators.
5. Load can be inductive with PF=0.8
6. Auto start function.
Easy
1. Sealed lead-acid maintenance free battery & Expandable (Option).
2. Intelligent LED or LCD display for operation guide & UPS working status.
3. Compact size and easy to move & space-saving.
Specification:
| Model | ASU-11001 | ASU-11002 | ASU-11003 | ASU-11006 | ASU-11010 | ASU-31010 | ASU-31015 | ASU-31020 | |
| Capacity | 1kVA | 2kVA | 3kVA | 6kVA | 10kVA | 10kVA | 15kVA | 20kVA | |
| Input(AC) | Phase | Single phase | Three phase | ||||||
| Voltage | 220V | 220V /380V | |||||||
| Voltage Range | 115V~300V | 176V~276V | 304V~478V | ||||||
| Frequency Range | 40~60Hz (Adjustable by software) | 46~54Hz | |||||||
| Power Factor | 0.95 | 0.98 | 0.95 | ||||||
| Output(AC) | Phase | Single phase | |||||||
| Voltage | 220V | ||||||||
| Dynamic Regulation | ± 2% | ± 1% | |||||||
| Frequency | 46Hz~54Hz (Line mode) 50 ± 0.2Hz (Battery mode) |
46Hz~54Hz (Line mode) 50 ± 0.05Hz (Battery mode) |
|||||||
| Power Factor | 0.7 | ||||||||
| System Efficiency (AC-AC) |
≥85% ( Line mode ) ≥83% (Battery mode) |
≥88% (Line
mode ) ≥88% (Battery mode) |
|||||||
| Wave Form | Pure Sine Wave | ||||||||
| THD (Total harmonic distortion) |
≤ 6% (At none
liner load) ≤3% (At liner load) |
≤ 7% (At none liner
load) ≤4% (At liner load |
≤ 6% (At none liner
load) ≤2% (At liner load |
||||||
| Crest Factor | 3:1 | ||||||||
| Battery | Type | Sealed lead acid battery , maintenance free battery | |||||||
| Voltage | 36V | 96V | 240V | ||||||
| Size (Standard type) | 12V/7.2Ah | 12V/9Ah | Depend on the capacity of external battery |
||||||
| Quantity | 3 | 8 | 20 | ||||||
| Backup Time (Standard type) |
>5min | > 9 min | > 5min | > 7min | |||||
| Transfer Time | Ac line ↔Battery Mode | 0ms | |||||||
| Ac line ↔Bypass Mode | < 4ms | 0 ms | |||||||
| Indicator | LED | Bypass mode (line/bypass LED) Line mode (line/inv/load level LED) Battery mode (bat/inv/load battery level LED) Fault mode (Fault LED) |
|||||||
| Overload Capability |
Line mode | 108% ±5% ~150±5% for 30s, than transfer to bypass mode ≥ 150%± 5% for 300ms , than transfer to bypass mode |
105% ~130 for 10min ,than transfer to
bypass mode ≥ 130% for 1s , than transfer to bypass mode |
||||||
| Battery mode | 112% ±5% ~150±5% for 30s,than power off ≥ 150%± 5% for 300ms,than power off |
105% ~130 for 10s,,than power off ≥ 130% for 1s , ,than power off |
|||||||
| Protection | Low voltage alarm protection Auto shutdown protection ; Battery Protection Over charge voltage protection Battery leakage current protection |
||||||||
| Audible Alarm | Battery mode : Battery low/charge fault ;
UPS fault ; Over load Bypass/zero and fire line reverse connection |
||||||||
| Audible Noise (1 meter) | <45dB | <50dB | ≤ 55dB | ≤ 60dB | |||||
| Communication Interface | RS232 (WINPOWER2003); INTELLIGENT SLOT(WEBPOWER Card/AS400 Card) |
RS232 (WINPOWER2003); INTELLIGENT SLOT(WEBPOWER Card/AS400 Card);Parallel Port (Parallel with other UPS) |
|||||||
| Cooling System | Fan Cooling | ||||||||
| Environment | Ambient Temperature | 0ºC
~ 40ºC (Altitude : 0m~1500m) 0ºC ~ 35ºC (Altitude : 1500m~3000m) |
0ºC ~ 40ºC (Altitude : 0m~1000m) | ||||||
| Humidity | < 95% | ||||||||
| Size (mm) W x D x H |
Machine Dimension | 145x400x220 | 195x330x455 | 260x717x570 | |||||
| Packing Dimension | 240x495x330 | 330x475x590 | 430x845x700 | ||||||
| Weight (kg) | Net (Standard / Long backup time type) | 13/7 | 32.2/14.5 | 84/35 | 93/38 | 38.5 (Long Backup time type) |
55(Long Backup time type | ||
| Gross (Standard / Long backup time type) | 14/8 | 33.3/15.8 | 93/44 | 102/48 | 49(Long Backup time type | 65(Long Backup time type | |||
1. As to required voltage , please refer to Form 1
2. The backup time according to customer demand , please contact us.
3. The weight of long backup time type is machine weight , not include
batteries.
4. All specifications are subject to change without prior notice.
5.
Catalogue Download
This is the detailed information for ASU-series, ASU-series. The information includes model, name, description and specification for ASU-series, ASU-series. Related Keywords : UPS,Power supply ASU-11001 ASU-11002 ASU-11003 ASU-11006 ASU-11010 ASU-31010 ASU-31015 ASU-31020
Please send your Inquiries for ASU-series, ASU-series to us. We will contact you soon. Please also check out the related product categories below.