AC Power Corp.
AC Power Corp. was founded in1989. In order to make the dream of green world come true, and bring a better environment to human, AC Power has taken a position on R&D and production of power source product, providing solution of power source to customer ever since the establishment of the company. For carrying out the mission, AC Power insists on the concept of [Value Innovation], creates customizing product and service by integrating internal and external resource and making an effort on personnel encouragement. Therefore, AC Power got a public praise as well as created professional image. So we make it [The Power You Trust!]

Facebook Plurk Twitter

APS-33 series , APS-series

Categories  > Line Conditioner >

Line Conditioner - 1~300KVA- APS Series (Microprocessor Controlled Type)

> APS-series



Product Name :

APS-series


Features & Advantages:

◇4 H :
HIGH Input Power Factor, HIGH VA Efficiency, HIGH Over Load Capacity, HIGH Reliability.

◇5L :

LOW Environmental Pollution ( Green Energy ), LOW Electromagnetic Wave Interference, LOW Audible Noise, LOW Maintenance Costs, LOW No Load Energy Consumption.

◇CLEAN :

Clean and constant AC Power output. No radiation interference to electromagnetic field (EMF); No transmitting interference to electrified wire fence.

◇FAST :

Fast Response Time (≦4mS./step).

◇FLEXIBLE :
Any loads are applicable. Generator friendly.

◇NEW :

CE approval. New Design; New Circuits; New Patent.

◇RELIABLE :
DSP/Microprocessor Control circuits increase the reliability and stability.

◇SAFE :
Automatic Electronic Bypass Protection, Over Load Protection, Over Range Protection to let your load well protected.

◇SAVE :
Superior No Load Energy Consumption reduces operating costs through utility savings compared to SCR type or Ferroresonant Transformer. Compact size & light weight saves your space and transportation fee.

◇STABLE :
Independent Phase Voltage Regulation. Characteristics will not be violated under 100% unbalance load.

◇WIDE :
+/-25% input voltage range is useable.


Specification:

Model APS-33010 APS-33015 APS-33022 APS-33030 APS-33045 APS-33060 APS-33075
Capacity 10kVA 15kVA 22kVA 30kVA 45kVA 60kVA 75kVA
Input(AC) Phase Three Phase
Voltage 208V/120V , 480V/277V form 1
Voltage Range ± 18% ± 18% (25% Option)
Frequency 47Hz ~ 63Hz
Power Factor 0.95 ~ 1
Output(AC) Phase Three Phase
Voltage 208V/120V , 480V/277V form 1
Frequency Same as Input Frequency
Power Factor ± 0.7 ~ 1
VA Efficiency ≥ 98% Full Load / No Load energy power consumption ≤ 0.2
Line Regulation ± 1% ~ ± 4% ± 1% ~ ± 2%
Load Regulation ± 1% ~ ± 4% ± 1% ~ ± 2%
Total Harmonic Distortion < 1% (additional waveform distortion
Response Time ≤ 4ms / Step
Indicator Voltmeter Show 0~300VAC for each phase
Ammeter Show R.S.T. Load's Current
LED Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply
Protection Over Range Power Auto Shut & Led Indicator
Over Load No Fuse Break 150% for 15Sec , 130% for 30Sec , 110% for 300Sec
Auto Bypass Led Indicator & Alarm
Noise Suppressors High energy surge absorber 、LC Filter、EMI Filter (option)
R.S.T. Phase Failure Led Indicator (option) & Alarm (option) & Auto shut off (option)
Overload Capacity 200% for 10 seconds ; 500% for 50ms
Audible Noise ≤ 50dB ≤ 55dB
Cooling System Natural cooling Fan cooling
Connections Terminal
Environment Ambient 0ºC ~ 40ºC
Humidity 0~95% (Non-condensing)

 

Model APS-33100 APS-33120 APS-33150 APS-331800 APS-33240 APS-3300
Capacity 100kVA 120kVA 150kVA 180kVA 240kVA 300kVA
Input(AC) Phase Three Phase
Voltage 208V/120V , 480V/277V form 1
Voltage Range ± 18% (25% Option)
Frequency 47Hz ~ 63Hz
Power Factor 0.95 ~ 1
Output(AC) Phase Three Phase
Voltage 208V/120V , 480V/277V form 1
Frequency Same as Input Frequency
Power Factor ± 0.7 ~ 1
VA Efficiency ≥ 98% Full Load / No Load energy power consumption ≤ 0.2
Line Regulation ± 1% ~ ± 2%
Load Regulation ± 1% ~ ± 2%
Total Harmonic Distortion < 1% (additional waveform distortion
Response Time ≤ 4ms / Step
Indicator LCD Display electrical parameters . stat of the control , memories of history events
LED Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply
Protection Over Range Power Auto Shut off (option) & Led Indicator
Over Load 150% for 15Sec , 130% for 30Sec , 110% for 300Sec
Auto Bypass Led Indicator & Alarm
Noise Suppressors High energy surge absorber 、LC Filter、EMI Filter (option)
R.S.T. Phase Failure Led Indicator (option) & Alarm (option)
Overload Capacity 200% for 10 seconds ; 500% for 50ms
Audible Noise < 45dB
Cooling System Air force Fan
Connections Terminal Copper Busbar
Environment Ambient 0ºC ~ 40ºC
Humidity 0~95% (Non-condensing)

* Input & Output Voltage please refer to FORM 1

1. Other Input Ranges are on request.
2. Custom-made specifications are on request.
3. All specifications are subject to change without prior notice.
4.Catalogue Download




This is the detailed information for APS-series, APS-33 series. The information includes model, name, description and specification for APS-series, APS-33 series. Related Keywords : AC,Automatic,AVR,Changed,Conditioner,Controlled,Converter,Corp,DC,Frequency,Ground,Inductive,Line,Manufacturer,Microprocessor,Military,Online,Phase,Power,Programmable,Regulator,SCR,Shore,Source,Stabilizer,Supply,Taiwan,Tap,Three,Units,UPS,Variable,Voltage



Please send your Inquiries for APS-series, APS-33 series to us. We will contact you soon. Please also check out the related product categories below.


Designed by Web Builder & Trade Associated with AsianNet
Address :  3F., No.200, Gangqian Rd., Neihu District, Taipei City 11494, Taiwan (R.O.C.)
Telephone :  +886 2 2627 1899  Fax :  +886 2 2627 1879  
E-Mail : sales@acpower.net