AC Power Corp.
Product Name:
AFC Series-Single Phase In Single Phase Out (0.5~30kVA)
Description:
l
One key for
shutdown when fault.
l
Quick response
speed.
Response time
≤2ms.
l
High accurate
measurement for parameter:
²
Voltage, 0.15%FS+4COUNT;
²
Current, 0.2%FS+4COUNT;
²
Frequency, 0.1%;
²
Power, 0.3%FS+4COUNT.
l
Output voltage:
5~300V continuous adjustable.
Quick & convenient 3 scales of preset voltage for high and low voltage
simulation:
²
High: +10%~+25% of preset voltage;
²
Medium: preset voltage;
²
Low: -10%~-30% of preset voltage.
l
Pure output
sine-wave.
(Please see specification table).
l
Well protection
and fault alarm function: Input no-fuse breaker; electronic circuit instant trip for over voltage,
over current, over load, over temperature and short circuit protection and alarm
system.
l
Power module
design patent.
Specification:
Model
AFC-500W
AFC-1KW
AFC-11003
AFC-11005
AFC-11008
AFC-11010
AFC-11015
AFC-11020
AFC-11030
Capacity (kVA)
0.5
1
3
5
8
10
15
20
30
Circuit Type
Transistor amplifier type
IGBT/PWM
type
Input
Phase
Single phase
Wave
Sine wave
Voltage
220V
Voltage range
220V±15%
Frequency range
50Hz±3Hz or 60Hz±3Hz
Power factor
0.85
Output
Phase
Single phase
Wave
Sine wave
Voltage
Low
0~150V(L-N)
5V~150V(L-N)
High
0~300V(L-N)
10V~300V(L-N)
Frequency
47~63Hz, 50Hz, 60Hz
Frequency regulation
≤0.01%
Max. current
High (A)
2.1
4.2
12.5
20.8
33.3
41.7
62.5
83.3
125.0
Low (A)
4.2
8.4
25
41.7
66.7
83.3
125.0
166.7
250.0
System
Power regulation
±0.2%
<1%
Load regulation
±0.2%
±1% (linear load)
Total harmonic distortion (THD)
0.2%
2%
(linear load)
Efficiency
≧70%
≧90%
Response time
≤5μs
≦2ms
Wave factor
1.4:1
3:1
Protection device
Input no-fuse breaker, output no-fuse breaker,
electronic circuit instant trip for over/low voltage, over current, over
load, over temperature and short circuit protection and alarm system
Input no-fuse breaker, electronic circuit
instant trip for over/low voltage,
over current, over load, over temperature and
short circuit protection and alarm system
Indicator
Display
LED
Voltage
Show range: 0~600V, analytic degree: 0.1V,
Current
Show range: 0~700A, analytic degree:
0.01A(<100A)/0.1A(≥100A),
accurate degree: 0.2%FS+4COUNT
Power
4 COUNT digitally watt meter
Show range: 3kW~75kW, analytic degree:
0.01kW(<10kW)/0.1kW(≥10kW),
accurate degree: 0.3%FS+4COUNT
Frequency
Show range: 0~999.9Hz, analytic degree: 0.1Hz,
accurate degree: 0.1%
Environment
Insulation resistance
DC500V
≥20MΩ
Withstand voltage insulation
AC 1800V
5mA/1Min
Cooling system
Fan cooling
Temperature
0℃~40℃
Humidity
0~90% (Non-condensing)
Altitude
≤1500m
Case No.
①
②
③
④
Weight(kg)
44
89
73
89
200
210
240
280
330
Remarks:①
Custom-made specifications are discussible;
② All specifications are subject to change without prior notice.
accurate degree:
0.15%FS+4COUNT
analytic degree: 1W
This is the detailed information for AFC Series-Single Phase In Single Phase Out (0.5~30kVA), AFC 11 Series. The information includes model, name, description and specification for AFC Series-Single Phase In Single Phase Out (0.5~30kVA), AFC 11 Series. Related Keywords : AFC-500W AFC-1KW AFC-11003 AFC-11005 AFC-11008 AFC-11010 AFC-11015 AFC-11020 AFC-11030