Super Wide Input Frequency Window Benefits: AEU11 Series (1 / 2 / 3 / 6 / 10kVA ) UPS
AEU31 Series (10 / 15 / 30kVA ) UPS
AEU33 Series (20 / 30 / 40 / 60kVA ) UPS
Online Operation when Input Phase Fail Self-diagnosis Auto-switch between Boost and Float Recharging Temperature Compensation Module-designed DC Charge (for AEU11 / AEU31 ) ■We are authorized
distributor of Emerson Hipulse 7000 series (80kVA , 120kVA,160kVA
Super Wide Input Voltage Window
When one phase fails , can operate in on-line mode load equal to 50% of
the rating capacity.
When two phase fails , can operate in on-line mode load equal to 25% of the
rating capacity.
Intelligent Battery
Management
Auto-adaptable on EOD (End of Discharge) Adjustment
and automatically adjust the EOD for best performance of the battery . In
this way , over-discharge of
battery is avoided.
200kVA , 300kVA, 400kVA,500kVA,600kVA,800kVA) with the special features of three
phases input and tree phase output (380/400/415Vac) and parallel system which
can extend
to 6 units with/without MSS.
Specification:
Model
AEU-11001
AEU-11002
AEU-11003
AEU-11006
AEU-11010
AEU-11001L
AEU-11002L
AEU-11003L
AEU-11006L
AEU-11010L
Capacity
1kVA
2kVA
3kVA
6kVA
10kVA
Input (AC)
Phase
Single phase
Voltage
220V
Voltage Range
160 ~276V , full load
120 ~160V , linearly decreased load
120V , half load176 ~276V , full load
120 ~176V , linearly decreased load
120V , half load
Frequency Range
45 ~ 55 Hz
Power Factory
0.99
Output(AC)
Power Factory
Standard 0.7 (Can reach 0.8 )
Voltage
220V ± 1%
THD
(Total harmonic distortion)< 3% (at linear load)
< 5% (at no linear load)< 4% (at linear load)
< 5% (at no linear load)
Frequency
When the mains frequency is within 50Hz ±
10% , the output phase differential is less than 3 degrees ;
When the mains exceed the limitation or the battery is under operation ,
the output frequency is 50Hz ± 0.2%
Overload Capacity
105% ~ 125% for 5min ; 125% ~ 150% for 10s
; > 150% for 200ms
Crest Factor
3 : 1
Bypass Voltage
120 ~ 253Vac
System Efficiency
Up to 90% (On battery mode , can reach 95%)
Battery
Type
Sealed lead acid , maintenance free battery
(12V / 7Ah)
Voltage
36Vdc
96Vdc
120Vdc
240Vdc
Quantity
3
8
10
20
40
Backup Time (Full load)
> 6min
> 8min
Charging time (Standard type)
8Hr
Charging time (Long Backup time type)
7A
6A
5A can be expanded to 9A bye parallel
connection
Transfer Time
0
Dynamic Regulation
Rated voltage : < ±5% , at 0 ~ 100% load or
100% ~ 0 load
Audible Noise (1 meter)
< 45dB
Indicator
LED
LED + LCD
(Chinese and English display
selectable)
Safety Standard
CCEE (EN60950)
Bearable Maximum Input Voltage
320Vac , 1Hour (Static)
EMI Standard
EN50091-2 Class B
Interference Standard
IEC 1000-4-2 , 3 , 4 , 5 , 11 Level III
MTBF (System)
200,000 hr
Surge Protection
Satisfy the class IV requirements specified
by IEC60664-1 , that is the ability to withstand 1.2/50μs
+ 8/20μs no lower than 6kV/3kA
Size (mm) W x H x D
155x245x400
210x400x500
280x635x670
280x875x770
Weight (kg) (standard type /long backup tome type )
14 / 8
40 / 20
45 / 21
94 / 50
178 / 80
Redundancy Technology
Hot backup through series connection (6K ,
10K)
1. Additional features and options available, please contact our sales representative.
2. One year warranty.
3. All specifications are subject to change without notice.
4. Catalogue Download
This is the detailed information for AEU-11 Series, AEU-11 Series. The information includes model, name, description and specification for AEU-11 Series, AEU-11 Series. Related Keywords : AEU-11001 / AEU-11001L AEU-11002 / AEU-11002L AEU-11003 / AEU-11003L AEU-11006 / AEU-11006L AEU-11010 / AEU-11010L